VSB2H0NB-00000-000 [Carling Technologies]
Rocker Switch,;型号: | VSB2H0NB-00000-000 |
厂家: | Carling Technologies |
描述: | Rocker Switch, |
文件: | 总16页 (文件大小:3499K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
V-Series
V-Series
CONTURA IV, V, VII SWITCHES
The V-Series Contura IV, V, & VII snap-in rocker switches offer countless unique options including choices
for ratings, circuits, colors, illuminations and symbols. These single or double pole switches feature removable
actuators in a choice of actuator styles and colors, and can be illuminated with either oval or bar shaped lenses.
Actuators may also be purchased and stocked separately. An optional plug-in terminal connector enables pre-
wiring of wire harnesses.
The Contura switches with sealed option, are certified to IP66/68, signifying complete protection against dust
and prolonged spray and submersion under pressure, and are recognized to UL1500 - Ignition Protection
for Marine Products. These switches are vibration, shock, thermoshock, moisture and salt spray resistant.
Temperature ratings range from -40°C to +85°C.
Resources:
Download 3D CAD Files
IGS
STP
Watch Product Video
Product Highlights:
Countless options for ratings, circuits, colors,
illuminations and legends
Typical Applications:
On/Off Highway Equipment
Marine
Military Armored Vehicles
Mining Machinery and Equipment
Any application requiring environmental
protection
Certified to IP66/68 for front panel components
Vibration, shock, thermoshock, moisture and salt
spray resistant
Temperature range from -40°C to +85°C.
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
2
V-Series Contura Sealed Rocker Switches - Design Features
V-Series Switch
DESIGN FEATURES
INTERCHANGEABLE ACTUATORS
Panel redesign is a snap with our wide
range of rocker styles. Achieve maximum
design variety with minimum inventory.
Simply swap rockers to create an entirely
new look for your panel.
DUAL SEAL PROTECTION
CLEAN CONNECTIONS
Seals out water, dust,
Options for both eight and ten
terminal base styles with AMP &
Packard compatible connectors
affords myriad circuit options
while providing ease of assembly.
debris, and enables switch
certification to IP66/68 for
front panel components.
MULTIPLE LIGHTING OPTIONS
BRASS ROLLER PIN
Robust mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
SILVER PLATED BUTT
CONTACT MECHANISM
Providing 50k to 100k
electrical cycles and
a variety of different
electrical ratings.
OPTIONAL PANEL SEAL
Helps prevent water/dust
ingress behind panel.
In addition to Incandescent
lamps, our LED illumination is
offered in a wide array of light
intensities, colors, as well as
dual level, tri-color, and flashing
options.
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches - Actuator Options & Accessories |
3
Contura II & III
Contura X
The Contura II & III actuators are
constructed of thermoplastic
The raised bracket/bezel on the
Contura X helps prevent inadvertent
actuation of the rocker, as well as
preventing debris from being trapped
under the actuator. This curved rocker
style is available with a variety of
lenses and legends.
polycarbonate and are offered with
a hard nylon overlay or a “soft-touch”
elastomer overlay. These models
incorporate aesthetic designs on
the top and bottom of the rocker
featuring two rows of raised “bumps”
on the Contura II and three “indented”
lines on the Contura III.
Contura IV
Contura XI
The Contura IV’s “Shape to create
a Shape”actuator works with the
curves, contours & advanced styling
of the latest panel designs, flowing
with these advanced curves & radii.
This actuator style fits on the Contura
flush bracket/bezel.
The raised bracket/bezel on the
Contura XI helps prevent inadvertent
actuation of the rocker, as well as
preventing debris from being trapped
under the actuator. This convex style
rocker is available with a wide variety
of lenses and legends.
Contura XII
Contura V
The Contura XII version features a
paddle style actuator with the raised
bracket/bezel of Contura X and XI. The
contoured handle design provides
intuitive recognition and ease of
operation and is available with all
Contura X and XI lens and legend
offerings.
The symmetrically curved Contura
V actuator provides the perfect
complement to the Contura IV’s
“Shape to create a Shape”design
concept. With its flush style mounting
bracket, Contura V can be mounted in
between two Contura IV’s, by itself, or
in groups.
Contura VI (WAVE)
Contura XIV
The Contura VI WAVE sealed rocker
switches, when used in a row, create
an uniquely appealing“wave”design
on your panel. A variety of colors and
finishes are available for both rocker
and wave insert. Contura VI features
bar and oval lenses.
The Contura XIV represents a sleek new
crossover rocker design which should
appeal to Trucks, Buses and Heavy
Vehicles as well as the Marine Industry.
Intuitive feel is provided by recessed
ridges along with a Center Groove
which effectively defines the boundary
between top and bottom switch
functions.
Contura VII
Illuminated Indicators
Contura VII featuring gently
& Accessories
curved corners and edges assuring
compatibility with most any panel
design. Intuitive feel is maximized
by the use of 2 embossed circular
pads located at opposite ends of
the rocker. Any combination of Bar
or Oval style lenses can be located
in the pads providing a truly unique
look, exclusive to Contura VII.
Alert operator of systems functions
or malfunctions, are offered with
removable/replaceable lamps in
Contura II, II, V or X styles. Accessories
include connectors, mounting panels,
hole plugs, panel seals, and actuator
removal tools. Refer to accessories page
for full details
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
V–Series Contura Sealed Rocker Switches - General Specifications
Electrical
Contact Rating
Agency Certifications
.4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
Environmental
Sealing
Sealed version: IP66/68, this rating
applies to front panel components of
the actual switch only, and signifies
complete protection against dust as
well as powerful jets of water.
Mixed Flowing Gas (MFG) Class III
3 year accelerated exposure per
ASTM B-827, B-845 Silver and gold
contacts
6A, 125VAC L
1500 Volts RMS
50 Megohms
Dielectric Strength
Insulation Resistance
Initial Contact Resistance 10 milliohms max. @ 4VDC
Corrosion
Life
50,000 - 100,000 cycles circuit
dependent
Silver alloy, silver tin-oxide, fine
silver
Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect
terminations standard. Solder lug,
Wire Lead
Contacts
Terminals
Operating Temp.
Vibration 1
-40°C to +85°C
Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10G’s
10-500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test, pre and post test contact
resistance.
Mechanical
Vibration 2
Resonance search
24-50 Hz 0.40 DA
Endurance
150,000 cycles minimum
circuit dependent
50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Random
Physical
24 Hz 0.06 PSD-Gsq/Hz
Lighted
Incandescent - rated 10,000
hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10μ
seconds chatter.
Seals
Base
Internal
Optional external gasket panel seal
Polyester blend rated to 125°C with
a UL flammability rating of 94V0.
Hard Surface: Basic actuator
structure molded of thermoplastic
polycarbonate with a hard Nylon 66
thermoplastic surface overlay.
Soft Surface: Basic actuator structure
molded of thermoplastic polycarbonate
with an elastomer overlay.
Shock
Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre and post
test contact resistance.
Contura II,III,IV,V,
VI, VII Actuator
Salt Spray
Dust
Per Mil-Std 202F, Method 101D, Test
Condition A, 96 Hrs. Sealed version only.
Mil STD 810, Method 510.2 Air Velocity
300 Ft/Min Duration 16Hr
Per Mil-Std 202F, Method 107F, Test
Cond. A, -55°C to +85°C. Test criteria -
pre and post test contact resistance
Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance
All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to
conformance with EC directive
94/25/EC for marine products.
Thermal Shock
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C
Lens
Contura XIV
Polycarbonate rated at 100°C
Polycarbonate lens/sub-rocker with
ABS shell
Moisture Resistance
Ignition Protection
Actuator Travel (Angular Displacement)
2 position
3 positions
18°
9° from center
Mounting Specifications
Panel Thickness Range
.830[21.08]
Gaskets Acceptable Panel Thickness
0
1
.030 to .250 (.76 to 6.35mm)
.030 to .109 & .147 to .157
(.76 to 2.77mm & 3.73 to 3.98mm)
TEST CUT
HOLE IN
ACTUAL
1.450[36.83]
MATERIAL
Recommended: No gasket with panel
thickness of .032, .062, .093, .125,.187 or .250
SWITCH
MOUNTING HOLE
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches - Contura IV - Ordering Scheme |
5
V 1 D A B T 0 B E P C 00 0 00
8
9
10
Lens
11
Color
12
Legend
13
Legend
Orientation Lens Legend
14
Actuator
1
2
3
4
5
6
7
Bracket
Actuator
Series
Circuit
Rating
Termination Illumination Lamp
Lamp
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
V
No lamp
Neon
0
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7
1 - - 4
2 - - 5
3 - - 6
LED*
Red
superbright superbright
( ) - momentary
Amber
Green
Red
R
2VDC
A
B
C
D
L
F
6VDC
M
N
P
G
H
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
Terminals 7, 8, 9 & 10 for lamp circuit only.
12VDC
24VDC
T
JV
* Consult factory for “daylight bright” LED options. Typical current draw for
LED is 20ma.
Position:
1
2
Connected Terminals
NONE
3
1 & 2, 4 & 5
OFF
1
8 FLUSH BRACKET COLOR , PANEL SEAL
SP DP
2 & 3, 5 & 6
ON
Black
B
C
White
W
Y
Gray
G
H
1
2
3
4
5
6
7
8
A
B
C
D
F
No Seal
One Seal
(ON)
ON
NONE
OFF
NONE
(OFF)
ON
ON
NONE
ON
NONE
(ON)
9 ACTUATOR
J
ON
OFF
ON
1,4
3,6
K
L
ON
OFF
(ON)
0
No Actuator
(ON)
OFF
(ON)
E
T
F
R
Contura IV, left orientation
SPECIAL CIRCUITS
Contura IV, left orientation, laser etched
Contura IV, right orientation
Contura IV, right orientation, laser etched
H*
2 & 3
2 & 3, 5 & 4
2 & 3
5 & 4
OFF
G*
S*
M*
R*
E*
2 & 3, 5 & 6
2 & 3, 5 & 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
5 & 6
2 & 3
1 & 2
OFF
Actuator orientation over terminals:
2 & 3
2 & 3
2 & 1
5 & 1
5 & 3
10 LENS
0 - No Actuator
Z - No Lens
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in
selection 4. External jumper between terminals 2 & 4 for circuit E are
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.
Clear White Amber Green Red Blue
1
2
3
4
5
6
7
8
9
A
8
G
H
J
K
L
M
N
P
R
S
T
C
D
E
F
U
V
W
Y
4
3 RATING
1
.4VA @ 28VDC Resistive
15A 24V
B
C
D
E
F
E F
20A 18V
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
1,5,6
M
N
11 ACTUATOR COLOR
.4VA/15A 24V
No Actuator 0
Black
Nickel
C
D
Gray
Pewter
H
E
Red
S
White
Y
4 TERMINATION / BASE STYLE
2
8 term 10 Term
Termination
Jumper
12 ACTUATOR LENS OR BODY LEGENDS
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
No
11 ON 12 OFF 13 I
OFF ON
14 O
A
J
B
K
5
No
O
I
Yes T2 to 5
3
No
No
No
No
15 O O 16 O O 17 O I 18 I O
C
5
D
6
F N
F
N
F
F
E
F
For additional legend options & codes, visit us at www.carlingtech.com.
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector assembly,
as it is detrimental to function and performance.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED
lamps only
1
2
3
4
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S
A
B
C
D
0
1
2
3
4
NONE
–
–
1
1
2
1
2
1
2
1
2
1
2
2
1
2
INDEPENDENT
DOWN
8 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
1 (+) 7 (–)
1 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
3 (+) 6 (–)
8 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
8 (+) 7 (–)
10 (+) 9 (–)
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
UP
(used with codes 11-18 in selection 12) Selection 14 required when switch
requires two legends. If the two legends consist of one lens and one
body legend, lens legend must be specified in selection 12; body legend
specified in selection 14.
DOWN
DOWN
E
F
5
6
7
UP
UP
For legend options & codes, visit us at www.carlingtech.com.
INDEPENDENT
UP
Notes:
G
INDEPENDENT
UP
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
Custom colors are available. Consult factory.
H
U
Z
Y
INDEPENDENT
INDEPENDENT
INDEPENDENT
White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
Gloss brow is on left side of E actuator and right side of F actuator.
Additional ratings available. See V-Series Switch Accessories page.
Laser etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
3
4
5
SINGLE POLE SWITCHES ONLY
J
8
1
2
1
2
DOWN
3 (+) 8 (–)
6 (+) 7 (–)
8 (+) 7 (–)
6 (+) 7 (–)
INDEPENDENT
INDEPENDENT
INDEPENDENT
K
W
6
Pewter and nickel colors only available with laser etched actuator.
DOUBLE POLE SWITCHES ONLY
L
9
R
T
1
1
1
2
1
2
DOWN
UP
3 (+) 6 (–)
3 (+) 6 (–)
3 (+) 6 (–)
1 (+) 4 (–)
1 (+) 4 (–)
3 (+) 6 (–)
M
N
DOWN
DOWN
UP
P
V
UP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
V-Series Contura Sealed Rocker Switches - Contura V - Ordering Scheme
V 1 D A B T 0 B G P C 00 0 00
8
9
10
Lens
11
Color
12
Legend
13
Legend
Orientation Lens Legend
14
Actuator
1
2
3
4
5
6
7
Bracket
Actuator
Series
Circuit
Rating
Termination Illumination Lamp
Lamp
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
V
No lamp
Neon
0
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7
1 - - 4
2 - - 5
3 - - 6
LED*
Red
superbright superbright
( ) - momentary
Amber
Green
Red
R
2VDC
A
B
C
D
L
F
G
H
J
6VDC
M
N
P
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
Terminals 7, 8, 9 & 10 for lamp circuit only.
12VDC
24VDC
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for
LED is 20ma.
Position:
1
2
3
1 & 2, 4 & 5
OFF
1
8 FLUSH BRACKET COLOR , PANEL SEAL
SP DP
2 & 3, 5 & 6 Connected Terminals
Black
B
C
White
W
Y
Gray
G
H
1
2
3
4
5
6
7
8
A
B
C
D
F
ON
(ON)
ON
NONE
NONE
NONE
NONE
NONE
OFF
No Seal
One Seal
OFF
(OFF)
ON
ON
ON
(ON)
J
ON
ON
9 ACTUATOR
K
L
ON
OFF
OFF
(ON)
0
No Actuator
Contura V
Contura V, laser etched
(ON)
(ON)
G
P
SPECIAL CIRCUITS
H*
2 & 3
2 & 3, 5 & 4
2 & 3
5 & 4
OFF
G*
S*
M*
R*
E*
2 & 3, 5 & 6
2 & 3, 5 & 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
5 & 6
2 & 3
1 & 2
OFF
10 Lens
2 & 3
0 - No Actuator
Z - No Lens
style & location: #1 / #2
2 & 3
2 & 1
5 & 1
Clear White Amber Green Red Blue
5 & 3
1
2
3
4
5
6
7
8
9
A
8
G
H
J
K
L
M
N
P
R
S
T
bar
bar/bar
oval
oval/bar
oval/oval
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in
selection 4. External jumper between terminals 2 & 4 for circuit E are
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.
C
D
E
F
U
V
W
Y
4
3 RATING
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
1
.4VA @ 28VDC Resistive
15A 24V
B
C
D
E
F
20A 18V
1,3,5
20A 12V
11 ACTUATOR COLOR
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
No Actuator 0
Black
Nickel
C
D
Gray
Pewter
H
E
Red
S
White
Y
M
N
.4VA/15A 24V
2,6
12 ACTUATOR LENS OR BODY LEGENDS
11 ON 12 OFF 13 I
OFF ON
14 O
4 TERMINATION / BASE STYLE
8 term 10 Term
Termination
Jumper
O
I
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
No
15 O O 16 O O 17 O I 18 I O
A
J
B
K
5
No
F N
F
N
F
F
Yes T2 to 5
3
No
No
No
No
C
5
D
6
For additional legend options & codes, visit us at www.carlingtech.com.
E
F
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector assembly,
as it is detrimental to function and performance.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED
lamps only
1
2
3
4
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S
A
B
C
D
0
1
2
3
4
NONE
–
–
1
1
2
1
2
1
2
1
2
1
2
2
1
2
INDEPENDENT
DOWN
8 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
1 (+) 7 (–)
1 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
3 (+) 6 (–)
8 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
8 (+) 7 (–)
10 (+) 9 (–)
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
UP
(used with codes 11-18 in selection 12) Selection 14 required when switch
requires two legends. If the two legends consist of one lens and one
body legend, lens legend must be specified in selection 12; body legend
specified in selection 14.
DOWN
DOWN
E
F
5
6
7
UP
UP
For legend options & codes, visit us at www.carlingtech.com.
INDEPENDENT
UP
Notes:
G
INDEPENDENT
UP
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
Custom colors are available. Consult factory.
H
U
Z
Y
INDEPENDENT
INDEPENDENT
INDEPENDENT
White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators. Custom colors are available, consult factory.
Laser Etched rocker only available with lens code Z & actuator colors black,
nickel or pewter.
3
SINGLE POLE SWITCHES ONLY
J
8
1
2
1
2
DOWN
3 (+) 8 (–)
6 (+) 7 (–)
8 (+) 7 (–)
6 (+) 7 (–)
4
5
6
Additional ratings available. See V-Series Switch Accessories page.
Nickel and Pewter colors only available with laser etched actuator.
Consult factory for laser etched lens callout.
INDEPENDENT
INDEPENDENT
INDEPENDENT
K
W
DOUBLE POLE SWITCHES ONLY
L
9
R
T
1
1
1
2
1
2
DOWN
UP
3 (+) 6 (–)
3 (+) 6 (–)
3 (+) 6 (–)
1 (+) 4 (–)
1 (+) 4 (–)
3 (+) 6 (–)
M
N
DOWN
DOWN
UP
P
V
UP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches - Contura IV & V Locking - Ordering Scheme |
7
V 1 D A S W 0 B J Z E 00 0
8
9
10
Lens
11
Function
12
Legend
13
1
2
3
4
5
6
7
Bracket
Actuator
Legend
Orientation
Series
Circuit
Rating
Termination Illumination Lock
Lamp
1 SERIES
V
7 LAMP
Lamp above terminals 3 & 6 end of switch
No lamp
Neon
0
1 125VAC 2 250VAC
3
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
LED*
Red
superbright superbright
Terminal Connections as viewed
( ) - momentary
Amber
Green
Red
R
from bottom of switch:
SP - single pole - uses terminals 1, 2 & 3.
2VDC
A
B
C
D
L
F
G
H
J
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
6VDC
M
N
P
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
Terminals 7, 8, 9 & 10 for lamp circuit only.
12VDC
24VDC
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for
LED is 20ma.
Position:
1
2
3
1
8 FLUSH BRACKET COLOR , PANEL SEAL
SP DP
2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
Black
B
C
White
W
Y
Gray
G
H
1
4
6
7
8
9
A
D
J
ON
ON
NONE
NONE
OFF
OFF
ON
No Seal
One Seal
ON
ON
K
L
ON
(ON)
OFF
OFF
(ON)
(ON)
ON
OFF
9 HARD SURFACE ACTUATOR
N
NONE
CONTURA IV:
Orientation
Left
Black Gray Red
White
M
S
J
K
P
L
4
3 RATING
Right
N
R
1
.4VA @ 28VDC Resistive
15A 24V
B
C
D
E
F
Actuator orientation over terminals:
3,6
3,6
1,4
1,4
CONTURA V:
Orientation
20A 18V
Black Gray Red
White
Y
20A 12V
U
V
W
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
Actuator orientation over terminals:
M
N
.4VA/15A 24V
5
10 LENS
4 TERMINATION / BASE STYLE
Z - No Lens
8 term 10 Term
Termination
Jumper
No
Clear White Amber Green Red Blue
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
A
G
B
H
C
J
D
K
E
L
F
M
bar lens
oval lens
A
J
B
K
5
No
Yes T2 to 5
3
No
No
No
No
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
C
5
D
6
E
F
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector assembly,
as it is detrimental to function and performance.
1
11 ACTUATOR LOCK FUNCTION AND COLOR
3
Lock Color
Match Actuator
Black
Up
A
B
C
D
E
Down
Up & DownCenter
H
J
R
S
T
V
W
N
1
2
3
4
5
6
White
K
L
5 ILLUMINATION & SWITCH SEALING
Red
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED
lamps only
Safety Orange
Gray
M
G
F
Sealed Unsealed Lamps
Illumination Type Lamp wired to Terminals
S
C
H
0
3
Z
NONE
–
–
2
2
UP
3 (+) 7 (–)
2
12 ACTUATOR LENS OR BODY LEGEND
00 - No Legend
INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
21
22
23
24
I
M
R
1
UP
3 (+) 6 (–)
OFF ON
O
25
O
F
F
26 O
27 O
28 I
6 LOCK
N
Lock above terminals 1 & 4 end of switch.
6
W
low profile lock
Y
high profile lock
For additional legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
13 LEGEND ORIENTATION
1
2
Custom colors are available. Consult factory.
0
1
2
3
4
No legend
White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
Orientation 1
Orientation 2
Orientation 3
Orientation 4
3
4
5
6
Additional ratings available. See V-Series Switch Accessories page.
Located at T3-6 end of switch.
1
2
3
4
Contura V style only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
V-Series Contura Sealed Rocker Switches - Contura VII - Ordering Scheme
V 1 D A B T 0 B Z R C 00 0 00
8
9
10
Lens
11
Color
12
Legend
13
Legend
Orientation Lens Legend
14
Actuator
1
2
3
4
5
6
7
Bracket
Actuator
Series
Circuit
Rating
Termination Illumination Lamp
Lamp
6,7 LAMP (same coding for both selections)
1 SERIES
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
V
No lamp
Neon
0
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7
1 - - 4
2 - - 5
3 - - 6
LED*
Red
superbright superbright
( ) - momentary
Amber
Green
Red
R
2VDC
A
B
C
D
L
F
G
H
J
6VDC
M
N
P
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
Terminals 7, 8, 9 & 10 for lamp circuit only.
12VDC
24VDC
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for
LED is 20ma.
Position:
1
2
Connected Terminals
NONE
3
1 & 2, 4 & 5
OFF
1
8 FLUSH BRACKET COLOR , PANEL SEAL
SP DP
2 & 3, 5 & 6
ON
Black
B
C
White
W
Y
Gray
G
H
1
2
3
4
5
6
7
8
A
B
C
D
F
No Seal
One Seal
(ON)
ON
NONE
OFF
NONE
(OFF)
ON
ON
NONE
ON
NONE
(ON)
9 ACTUATOR
J
ON
OFF
ON
0
Z
No Actuator
Contura VII
K
L
ON
OFF
(ON)
(ON)
OFF
(ON)
Actuator orientation over terminals:
3,6
1,4
SPECIAL CIRCUITS
H*
G*
S*
M*
R*
E*
2 & 3
2 & 3, 5 & 4
2 & 3
5 & 4
OFF
2 & 3, 5 & 6
2 & 3, 5 & 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
5 & 6
2 & 3
1 & 2
OFF
10 LENS
2 & 3
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
2 & 3
2 & 1
5 & 1
5 & 3
0 - No Actuator
Z - No Lens
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in
selection 4. External jumper between terminals 2 & 4 for circuit E are
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.
White Amber Green Red Blue Lens style & location
6
7
8
9
A
1
B
C
D
E
F
2
G
H
J
M
N
P
R
S
4
T
U
V
W
Y
5
4
3 RATING
1
.4VA @ 28VDC Resistive
15A 24V
K
L
3
B
C
D
E
F
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
M
N
.4VA/15A 24V
1
11 ACTUATOR COLOR / THUMB PRINT COLOR
O
H
Y
N/A - No Actuator
Grey/Black
White/Black
C
S
Black/Black
Red/Black
4 TERMINATION / BASE STYLE
8 term 10 Term
Termination
Jumper
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
No
A
J
B
K
5
No
2
12 ACTUATOR LENS OR BODY LEGENDS
Yes T2 to 5
11 ON 12 OFF 13 I
OFF ON
14 O
3
No
No
No
No
C
5
D
6
O
I
15 O O 16 O O 17 O I 18 I O
E
F
F N
F
N
F
F
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector assembly,
as it is detrimental to function and performance.
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION
5 ILLUMINATION & SWITCH SEALING
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED
lamps only
Orientation 1
Orientation 2
Orientation 3
Orientation 4
Sealed Unsealed Lamps
Illumination Type Lamp wired to Terminals
0
1
2
3
4
NONE
–
–
A
B
C
D
1
1
2
1
2
1
2
1
2
1
2
2
1
2
INDEPENDENT 8 (+) 7 (–)
DOWN
UP
3 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
1 (+) 7 (–)
1 (+) 7 (–)
3 (+) 7 (–)
1
2
3
4
DOWN
DOWN
UP
E
F
5
6
7
14 ACTUATOR LENS LEGEND
UP
00
No legend this location / no actuator
INDEPENDENT 8 (+) 7 (–)
(used with codes 11-18 in selection 12) Selection 14 required when switch
requires two legends. If the two legends consist of one lens and one
body legend, lens legend must be specified in selection 12; body legend
specified in selection 14.
UP
3 (+) 6 (–)
G
INDEPENDENT 8 (+) 7 (–)
UP
3 (+) 7 (–)
H
U
Z
Y
INDEPENDENT 8 (+) 7 (–)
INDEPENDENT 8 (+) 7 (–)
INDEPENDENT 10 (+) 9 (–)
For legend options & codes, visit us at www.carlingtech.com.
Notes:
SINGLE POLE SWITCHES ONLY
J
Consult factory to verify horsepower rating for your particular circuit choice.
8
1
2
1
2
DOWN
3 (+) 8 (–)
1
2
Custom colors are available. Consult factory.
INDEPENDENT 6 (+) 7 (–)
INDEPENDENT 8 (+) 7 (–)
INDEPENDENT 6 (+) 7 (–)
White imprinting is standard on black actuators. Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
Additional ratings available. See V-Series Switch Accessories page.
Legends available for lighted oval lens version only
K
W
3
4
DOUBLE POLE SWITCHES ONLY
L
9
R
T
1
1
1
2
1
2
DOWN
UP
DOWN
DOWN
UP
3 (+) 6 (–)
3 (+) 6 (–)
3 (+) 6 (–)
1 (+) 4 (–)
1 (+) 4 (–)
3 (+) 6 (–)
M
N
P
V
UP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V–Series Contura Sealed Rocker Switches - Contura IV, V & VII - Dimensional Specifications |
9
Dimensional Specifications: in. [mm]
CONTURA IV
CONTURA V
CONTURA V
CONTURA VII
SHOWN WITH LARGE LENS
AND BAR LENS
SHOWN WITH
BAR LENS
SHOWN WITH
BAR LENS
SHOWN WITH
LOW PROFILE LOCK
1.922[48.56]
1.922[48.82]
1.922[48.56]
.080[2.03]
1.079
[27.40]
1.479
[37.57]
1.550
[39.37]
8 TERMINAL BASE
W/BARRIERS
8 TERMINAL BASE
W/O BARRIERS
10 TERMINAL BASE
W/O BARRIERS
10 TERMINAL BASE
W/O BARRIERS
1.020
[25.91]
1.020
[25.91]
0.985
[25.02]
.505
[12.83]
.505
[12.83]
.250 [6.35]
.031 [.78]
.250
[6.35]
X
.031
[.78]
.250
[6.35]
X
.031
[.78]
.820
[20.83]
.820
[20.83]
.960
[24.38]
.390
[9.90]
.960
[24.38]
.960
[24.38]
10 TERMINAL BASE
W/O BARRIERS
8 TERMINAL BASE
W/O BARRIERS
8 TERMINAL BASE
W/BARRIERS
10 TERMINAL BASE
W/O BARRIERS
8
1
7
4
8
1
7
4
2.029
[51.53]
2
5
2
3
5
6
3
6
9
10
SWITCH SHOWN
WITH VC1
CONNECTOR 10
TERMINAL
SWITCH SHOWN WITH
VCH CONNECTOR 8
TERMINAL
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
BOTTOM VIEW
TERMINAL
ARRANGEMENT
SWITCH SHOWN
WITH VC1
CONNECTOR 10
TERMINAL
10 TERMINAL BASE
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
V-Series Contura Sealed Rocker Switches - II to XIV - Circuit Diagrams
Circuit Diagrams:
CIRCUIT
CODE
CIRCUIT
CODE
CIRCUIT
CIRCUIT DIAGRAM
CODE
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
1
1
1
3
3
3
3
3
3
4
4
4
6
6
6
6
6
6
1
2
3
4
5
6
7
8
A
B
C
D
E
F
J
K
L
2
3
2
2
2
2
2
2
2
2
5
5
5
5
5
5
5
5
2
2
2
2
2
2
5
5
5
5
5
5
2
3
2
1
1
1
1
1
3
3
3
3
3
1
1
1
4
4
4
M
R
S
2
2
2
2
2
1
1
G
H
SYMBOL LEGEND
SYM.
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
4
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches - II to XIV - Lamp Circuit Diagrams, Hazard Warning Circuit Diagrams |
11
Lamp Circuit Diagrams:
LAMP CIRCUIT
CODE
LAMP CIRCUIT
CODE
LAMP CIRCUIT
CIRCUIT DIAGRAM
CODE
LAMP CIRCUIT
CODE
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
+3 +6
+8
+8
+3
-6
+3
-6
SPECIAL
#1
1
1
2
2
2
2
2
1
1
2
A / 1
B / 2
C / 3
D / 4
E / 5
F / 6
G / 7
H / Z
J / 8
L / 9
M / R
N / T
P / V
U / Y
-7
-7
-7
+8
+6
+3
+8
+3
+3
-6
SPECIAL
#3
1
2
1
1
2
2
2
-7
-7
-7
+8
+3
+3
+8
+1 +3 -4 -6
SPECIAL
#4
1
2
2
1
-7
-7
-7
-8
+1
+3
+6
+6
+1 +3 -4 -6
+3
1
2
1
1
-7
-7
+8
1
+10
2
+1 +3
+8
2
1
K / W
1
-7
-9
-7
(-)7
J-Series Hazard Warning Circuit Diagrams:
CIRCUIT
CODE
CIRCUIT
CODE
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
1
3
17 18 10(-)
1
10(-)
2
1
3
17 18
J1
J2
J3
J4
J5
2
5
8
2
5
8
11 13 3 14
17 18 10(-)
1
11 13
3
14
6
JA
5
8
5
1
3
3
17 18 10(-)
11 13
3 14
1
JJ
NOTE:
2
2
5
5
8
J circuits are available for all
non-locking V-Series styles.
Consult factory for partnumber details.
1
17 18 10(-)
11 13
3 14 15 12
6
16
SYMBOL LEGEND
1
JK
SYM.
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
V-Series Contura Sealed Rocker Switches - Stand-Alone Components
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS
Contura X & XI actuators without lenses separately:
Contura XII actuators without lenses separately:
VVR 6 1 00 1
VVP J 1 Z 21 1 00
1
2
3
Lens
4
5
1
2
3
Lens
4
Lens
5
6
7
Actuator Separately Actuator
Actuator
Legend
Legend
Orientation
Actuator
Style &
Color
Legend
Legend
Orientation
Legend
Style/Color Opening
Opening Opening
1 CONTURA X & XI ACTUATOR SEPARATELY
VVR
1 CONTURA XII ACTUATOR SEPARATELY
VVP
2 ACTUATOR STYLE & COLOR
2 ACTUATOR STYLE & COLOR
Black
Gray
White
3
8
Red
4
J
Black
K
Gray
N
White
M
Red
Contura X
Contura XI
1
6
2
7
9
3,4 LENS OPENING FOR
No lens Bar lens
Z
1
2
Square lens
1
3 LENS OPENING FOR
1
2
3
4
One bar lens
5
square lens on top/
bar lens on bottom
(Contura X only)
One bar lenses
One square lens
two square lens
2
5, 7 LENS OR BODY LEGEND
00 - No Legend
21
OFF
22
ON
23
O
24
I
25
O
26 O
27 O
28 I
4 ACTUATOR LENS OR BODY LEGEND
F
F
N
00 - No Legend this location
11 ON 12 OFF
OFF ON
13
I
O
14
O
I
For additional legend options & codes, visit us at www.carlingtech.com.
15 O O 16 O O 17 O I 18 I O
F N
F
N F
F
3
6 LEGEND ORIENTATION
0
1
2
No legend
For additional legend options & codes, visit us at www.carlingtech.com.
Orientation 1
Orientation 2
1
2
1
5 LEGEND ORIENTATION
0
1
2
3
4
No legend
Contura X, XI & XII actuator lens assembly separately:
Orientation 1
Orientation 2
Orientation 3
Orientation 4
1
2
3
4
VVL 2 1 00 0
1
2
Lens
Style
3
4
5
Lens Separately
Lens
Color
Legend
Legend
Orientation
Contura X, XI & XII top piece of 2-piece lens separately:
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
1 TOP OF LENS SEPARATELY
VVT
VVT 1
3
1
2
2 COLOR
1 Clear 2 Smoke 3 White
2 LENS STYLE
Lens Separately
Color
1
2
3
Bar lens
One Piece Square lens
Bottom of Two-Piece Square lens
5
Contura X, XI & XII actuator lens assembly:
3 TRANSLUCENT LENS COLOR
4
4
1
Clear
2
White
3
Amber
4
Green
5
Red
6 Blue
top lens
actuator stem
2
two piece
lens assembly
4 LENS OR BODY LEGEND
}
00 - No Legend
21
22
ON
23
24
posts mount toward actuator stem
bottom lens
OFF
O
I
1 piece lens/bar lens are positioned the same as bottom lens for assembly,
minus the top lens. Lenses snap in from bottom.
25
O
F
F
26 O
27 O
28 I
N
Notes:
1
If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2
must be chosen.
Center of actuator marking not available for Contura XII.
Legend is not available for bar style lens.
For additional legend options & codes, visit us at www.carlingtech.com.
2
3
4
5
3
5 LEGEND ORIENTATION
Not recommended with neon lamps.
0
1
2
3
4
No legend
Must also order top piece of 2 piece square lens separately.
Orientation 1
Orientation 2
Orientation 3
Orientation 4
1
2
3
4
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
V-Series Contura Sealed Rocker Switches - Accessories |
13
Easily integrate Contura products into your system, with Contura Accessories
Contura Connectors
Q.C. SELECTION GUIDE
WIRE
RANGE
PART NO
COMPANY
SERIES
ORIEN-
TATION
TIN
PLATED
BRASS
2
PLAIN
BRASS
AWG
MM
(REF)
02965580
02965471
02965470
02965469
12
3.0
12010601
(2)16-14
16-14
20-18
(2)1.0-2.0
1.0-2.0
.5-.8
TANG
PACKARD
58 SERIES
B
06288318
12084590
12052224
10
12
5.0
3.0
12015870
12020035
12015869
12052222
16-14
(2)22-18
20-18
20-22
16-12
(2) 16
18-14
22-18
1.0-2.0
(2).5-.8
.5-.8
TANG SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
PACKARD
METRI-PACK
630 SERIES
A
B
SYMBOL
12015832
60253-1
.35-.5
1.3-3
60253-2
AMP
(2) 1.3
.8-2
250 SERIES
FASTIN-FASTON
42100-1
60295-1
42100-2
60295-2
.3-.9
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
.820[20.83]
.820[20.83]
.770[19.56]
.920[23.37]
.920[23.37]
1.170[29.72]
A
A
B
A
B
A
B
PACKARD 630
PACKARD 630
VC2
PACKARD 630
PACKARD 630
VC1
VC1
VC2
.950[24.13]
B
AMP,
58
AMP, PACKARD 58
AMP
AMP
10P3ACKARD
2
1
8
7 4
5
69
10 3
2
1
8
7
4
5
6 9
AMP, PACKARD 58
AMP, PACKARD 58
3
2
1
8
7
4
5
6
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.466[37.24]
1.250[31.75]
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
VC1
VC2
VCH
CONNECTOR HOUSING
(For AMP terminals only)
CONNECTOR HOUSING
CONNECTOR HOUSING
Contura X Boot (P/N VB1-01)
Additional V-Series Ratings
1
.4VA @ 28VDC Resistive
4
5
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
1
1.050[26.67]
B
C
D
E
F
G
H
L
15A 24V
20A 18V
20A 12V
2.000[50.80]
20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
10A 14V, 6A, 14VT (circuit G only)
20A 6V
.757[19.23]
20A 3V
2
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
.4VA/20A 12V (combi-contact)
M
(combination gold/silver contacts for borderline dry circuit applications)
.4VA/15A 24V (combi-contact)
(combination gold/silver contacts for borderline dry circuit applications)
N
Contura II, III, IV, V, VI & VII Actuator
Removal Tool (P/N VRT)
3.99 [101.35]
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
O T P
1.
2.
Not available with Contura 7 or 14 rocker styles.
Rating L available with circuits 1, 4, A & D only.
INSERT POINTS UNDER
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
IN
.900 [22.86]
TOP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
14
V-Series Contura Sealed Rocker Switches - Accessories
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Contura Hole Plug
Dimensional Specifications: in. [mm]
1.450 [36.83]
TEST CUT
HOLE IN
VHP
.830 [21.08]
ACTUAL
CONTURA II,III HOLE PLUG
MATERIAL
1.240 [31.50]
1.820 [46.23]
VHP
CONTURA II,III HOLE PLUG
.430 [10.92]
VH2
STANDARD HOLE PLUG
(With wing serrations)
VH1
STANDARD HOLE PLUG
(No wing serrations)
2.000 [50.80]
(With VC1 connector attached)
1.067 [27.10]
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
VH3
VH4
CONTURA IV HOLE PLUG
(No wing serrations)
CONTURA IV HOLE PLUG
(With wing serrations)
1.928 [48.97]
1.020 [25.91]
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
VH5
VH6
CONTURA V HOLE PLUG
(No wing serrations)
CONTURA V HOLE PLUG
(With wing serrations)
(With wing serrations)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
Reps & Contact
15
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_04_2018
相关型号:
VSB2UJPB-00000-000
Rocker Switch, DPDT, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VSB2UVJB-00000-000
Rocker Switch, DPDT, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VSB3200-M3/54
Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, 200V V(RRM), Silicon, DO-201AD, HALOGEN FREE AND ROHS COMPLIANT, PLASTIC PACKAGE-2
VISHAY
VSB3200-M3/73
Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, 200V V(RRM), Silicon, DO-201AD, HALOGEN FREE AND ROHS COMPLIANT, PLASTIC PACKAGE-2
VISHAY
©2020 ICPDF网 联系我们和版权申明